Gas boilers - Floor-standing
Floor-standing gas boilers make a classic solution for gas heating especially of houses. One advantage could be the usage of forced flue gas exhaustion - especially if current chimney for secondary fuel source is used, f. e. boiler for solid fuels. Our boilers are prepared for priority water heating in the external reservoir.
Wall-hung boilers make an elegant solution for gas heating in the flats and modern basementless houses. A possibility of usage in other space saving rooms is matter of fact - with a possibility of flue gas installation to chimney or forced exhaustion (called turbo).
Regarding price rising of natural gas we have to underline an efficiency and austerity of condensing boilers. A spectrum of output of our condensing boilers can ensure an optimal heating not only in the flats and houses but they can be also used in the larger objects. The boilers are applied also at reconstruction because of their dimensions and variable system of flue system.
Floor-standing boilers
1. G36
- high life time of cast iron shell
- high efficiency up to 92 %
- optional sets of equithermal regulation
- prior heating of hot water
- ideal for replacement of boilers in old gravity systems
- a possibility of room regulation
Comfort of heating with the boiler G36 can be extended for equithermal regulation. It acts about an automatic regulation so called start-up temperature, where the temperature of heating water is regulated depending on movement of outside temperature. Outside sensor that is placed outside the building monitors changing the outside temperature all the time and regulation adapts the temperature of heating water all the time according to customer´s request.
Also heater OV 100L for prior hot water preparation can be ordered in the same design as the boiler G36. 100 l reservoir is insulated by polyurethane and double enamel coating in a connection with anode protection ensuring a long term life time.
2. G42, G42 ECO
- low polluting material content
- economy low temperature operation without rising the condensate and risk of corrosion of exchanger
- high life time of cast iron shell
- high efficiency up to 93 %
- reliability of regulating and safety elements
- optional sets of equithermal regulation as an additional equipment
- prior hot water heating
- a possibility of fitting by extract polluting material ventilator
Low temperature operation – low temperature cast iron boiler G42 (ECO) limits condensation rising by its top construction of cast iron units and also limits a danger of low temperature corrosion. Heating (high-efficiency) surfaces of the shell reach a high utilization of heat contained in the polluting materials. There is not necessary to keep the temperature of heating water above 50°C because at around 30°C of return water it does not give any damage on the boiler out.
Low contain of polluting materials of the boiler G42 ECO ensured eco-label for the boiler and meet the strictest European norms – for example also limits of “Blue Angel”. Due to its parameters it minimally weights our living environment.
Also heater OV 100L for prior hot water preparation can be ordered in the same design as the boiler G42 (ECO). 100 l reservoir is insulated by polyurethane and double enamel coating in a connection with anode protection ensuring a long term life time.
Comfort of heating with the boiler G42 (ECO) can be extended for equithermal regulation. It acts about an automatic regulation so called start-up temperature, where the temperature of heating water is regulated depending on movement of outside temperature. Outside sensor that is placed outside the building monitors changing the outside temperature all the time and regulation adapts the temperature of heating water all the time according to customer´s request.
3. G50
- Long service life and high economy of the cast-iron body
- Boiler communication with a superior control system
- Possibility of boiler connection into cascade
- Efficiency over 90 per cent
- Right/left version of a loading door
- Easy service
3. G90
- variable delivery in disassembled or assembled form
- easy cleaning of shell
- variable boiler construction enables assembly into two
- a possibility of programmable equithermal regulation ALBATROS
- a possibility of left or right boiler version
Hot-water boiler for low temperature heating system with forced water circulation intended for heating of medium and larger objects – for example schools, production shops, buildings of communication facilities and so forth.
4. G100
- delivery in disassembled or assembled form
- simple cleaning of shell
- variable boiler construction enables assembly into two
- pedestal is adapted for using a handling trolley
- a possibility of programmable equithermal regulation ALBATROS
- a possibility of left or right boiler version
Hot-water boiler for low temperature heating system with forced water circulation intended for heating of larger objects – for example of schools, health centres, production objects and so forth. The boiler installation into a boiler rooms of I. and II. category is possible at using of gas valve with automatic control of tightness
5. G300
- long life time and high economy efficiency of cast iron shell
- delivery in assembled or disassembled form including a burner
- boiler communication with superior regulation system
- regulating elements for heating water up to 115 °C (standardly 90°C) on request
- a possibility of connection the boilers into cascades
- right/left version of doors
- easily accessible places of measurement
Single row cast iron boiler with overpressure combustion chamber that are especially intended for heating of medium and larger objects. They approved as field proved, reliable, economy and also environmentally friendly in combination with recommended types of burners.
6. G700
- long life time and high economy efficiency of cast iron shell
- delivery in assembled or disassembled form including a burner
- boiler communication with superior regulation system
- regulating elements for heating water up to 115 °C (standardly 90°C) on request
- a possibility of connection the boilers into cascades
- right/left version of doors
- easily accessible places of measurement
Single row cast iron boiler with overpressure combustion chamber that are especially intended for heating of medium and larger objects. They approved as field proved, reliable, economy and also environmentally friendly in combination with recommended types of burners.
Are you interested in this product? Contact us using form below or contact us directly on e-mail info@mrs.cz or call +420 545 175 844 or +420 602 707 001.