Ecomax wood gasification boilers

Ecomax wood gasification boilers

The boiler has a drum welded from metal sheets with a thickness of 4-6 mm. In the upper part of the boiler there is a hopper shaft; the lower part contains a round combustion chamber. The two spaces are separated by a ceramic nozzle. In the front of the drum there is a blower used to move primary and secondary air into the combustion chamber. In the back there is a heat exchanger, a flue way, a flue duct and openings for cleaning.

Advantages of wood gasification boilers:

OPOP gasification boilers are supplied with electronic controllers allowing very simple operation. A REG05 microprocessor controller is built into the controller box. In the basic configuration, the controller regulates the output of the boiler on the basis of a preset water temperature in the heating system, or on the basis of a required temperature in a reference room, and it controls the operation of the circulation pump.

The large hopper shaft of these boilers allows the combustion of large pieces of wood, providing for a long combustion time. Therefore, repeated stoking is required only once every 10 hours. Due to its large volume, the combustion chamber is very easy to clean.

Gasification process:

The gasification process consists of the thermal separation of organic and inorganic substances. The wood material in the hopper is first heated and dried, and the released gases mix with secondary air in the area of the nozzle. The resulting gas mixture is then burned in the boiler's combustion chamber. The combustion gases are then released through the heat exchanger into the chimney. This process allows a boiler efficiency exceeding 80%. Wood must be combusted as dry as possible, or with a maximum moisture of 15%. Water is released from wet wood, and it then condenses on the inside of the boiler and the chimney. This leads to the formation of aggressive substances which significantly shorten the life of the boiler.

 

Boiler type
ECOMAX 25
ECOMAX 35
ECOMAX 42
Rated capacity kW
25
35
42
Quantity Hoppers dm3 120 170 200
Water volume dm3 60 68 78
Exhaust duct diameter mm 160 160 160
Maximum boiler width mm 640 640 712
Maximum boiler depth mm 870 1020 1120
Maximum boiler height mm 1290 1290 1480
Hopper depth mm 396 546 596
Maximum log diameter mm 220 220 220
Maximal log length mm 385 535 585
Operating chimney draught Pa 20-25 20-25 20-25
Maximum operating overpressure kPa 200 200 200
Maximum noise level dB 65 65 65
Efficiency % 83 81 79
Weight kg 320 360 454
Operating voltage VHz 230/50 230/50 230/50
Electric input W 21 21 41
Electric input with electronic control W 30 30 50
Protection   IP 20 IP 20 IP 20

 


Are you interested in this product? Contact us using form below or contact us directly on e-mail info@mrs.cz or call +420 545 175 844 or +420 602 707 001.

Ask a question about this product

Columns marked by * are required.